Characterization of Time-Averaged and Temporal Two-Phase Flow Structures in Aerated-Liquid Jets Using X-Ray Diagnostics

Characterization of Time-Averaged and Temporal Two-Phase Flow Structures in Aerated-Liquid Jets Using X-Ray Diagnostics

Kuo-Cheng Lin Alan L. Kastengren Scott J. Peltier Campbell D. Carter 

Taitech, Inc., USA

Argonne National Laboratory, USA

Air Force Research Laboratory, USA

Page: 
139-151
|
DOI: 
https://doi.org/10.2495/CMEM-V6-N1-139-151
Received: 
N/A
| |
Accepted: 
N/A
| | Citation

OPEN ACCESS

Abstract: 

The structure of the two-phase flow inside the nozzle of an aerated-liquid injector and in the near field of the discharged plumes was experimentally explored with synchrotron x-ray diagnostics, including x-ray radiography, x-ray fluorescence, and x-ray high-speed imaging. One axisymmetric beryllium aerated liquid injector featuring the inside-out aerating scheme was fabricated to mate with three aerating tube designs for the creation of two-phase flows. Water and nitrogen were doped with x-ray fluorescent elements at low concentrations to facilitate the x-ray diagnostics. Quantitative time-averaged liquid mass distributions for the two-phase mixture were successfully obtained from both radiography and fluorescence measurements. Averaged flow properties, such as liquid density and liquid velocity, at various cross-sections, were also derived from these measurements. Temporal formation and evolution of the two-phase mixture inside the aerated-liquid injector were also characterized with high-speed imaging. It was found that an annular flow is typically created in the two-phase mixture near the nozzle exit, despite the complex fluid dynamics in the liquid/gas interaction, flow passage volume change, and recirculation zone. The two-phase flow structures in the nozzle and the spray regions created from the present injector and aerating tube configurations are highly similar for a given injection condition. The major factor contributing to the similarity of the two-phase flow structures in the two regions may be the large area contraction ratio between the mixing chamber and the nozzle passage, which leads to a significant increase in flow speed and thus to aerodynamic stretching of the two-phase flow into fine structures.

Keywords: 

aerated-liquid jet, annular flow, beryllium, high-speed imaging, two-phase flow, x-ray radiography

 

  References

[1] Lefebvre, A.H., Wang, X.F. & Martin, C.A., Spray characteristics of aerated-liquid pressure atomizers. Journal of Propulsion and Power, 4, pp. 293–298, 1988. https://doi.org/10.2514/3.23066

[2] Sovani, S.D., Sojka, P.E. & Lefebvre, A.H., Effervescent atomization. Progress in Energy and Combustion Science, 27, pp. 483–521, 2001. https://doi.org/10.1016/s0360-1285(00)00029-0

[3] Mathur et al., Liquid JP-7 combustion in a scramjet combustor. AIAA Paper 2000-3581, August, 2000.

[4] Lin, K.-C., Rajnicek, C., McCall, J., Carter, C. & Fezzaa, K., Investigation of pureand aerated-liquid jets using x-ray phase contrast imaging technique. Nuclear Instruments and Methods in Physics Research Section A, 649(1), pp. 194–196, 2011. https://doi.org/10.1016/j.nima.2010.11.122

[5] Lin, K.-C., Carter, C., Smith, S. & Kastengren, A., Exploration of aerated-liquid jets using x-ray radiography. AIAA Paper 2012-0347, January, 2012.

[6] Lin, K.-C., Carter, C., Smith, S. & Kastengren, A., Exploration of near-field plume  properties for aerated-liquid jets using x-ray radiography. AIAA Paper 2014-1183, January, 2014.

[7] Lin, K.-C., Carter, C., Smith, S. & Kastengren, A., Characterization  of  aeratedliquid jets using simultaneous x-ray radiography and x-ray fluorescence measurements. Atomization and Sprays, to be published.

[8] Peltier, S., Lin, K.-C., Carter, C. & Kastengren, A., Characterization of flow structures inside an aerated-liquid injector using x-ray diagnostics. Experiments in Fluids, 58,    p. 111, 2017. https://doi.org/10.1007/s00348-017-2380-4

[9] Lin, K.-C., Kastengren, A.L., Carter, C. & Donbar, J., Exploration of two-phase flow structures in aerated-liquid jets using beryllium nozzles and x-ray fluorescence techniques. AIAA Paper 2017-0825, January, 2017

[10] Kastengren, A.L., Powell, C.F., Arms, D., Dufresne, E. & Wang, J., Spray diagnostics at the advanced photon source 7-BM beamline,” Proceedings of the 22nd Annual Conference on Liquid Atomization and Spray Systems, May, 2010.

[11] Kastengren, A.L. & Powell, C.F., Synchrotron x-ray techniques for fluid dynamics. Experiments in Fluids, 55(3), Article 1686, 2014. https://doi.org/10.1007/s00348-014-1686-8

[12] Kastengren, A.L., X-ray fluorescence as a gas-phase mixing diagnostic. Proceeding of Central States Section of the Combustion Institute Spring Technical Meeting, March 2014.

[13] XCOM: Photon Cross Sections Database, NIST Standard Reference Database 8 (XGAM), available at: http://www.nist.gov/pml/data/xcom/index.cfm

[14] Schneider, C.A., Rashband, W.S. & Eliceiri, K.W., NIH image to ImageJ: 25 years of image analysis. Nature Methods, 9, pp. 671–675, 2012. https://doi.org/10.1038/nmeth.2089